10kV Single-Phase Transformer

PRODUCT DETAIL / SINGLE-PHASE TRANSFORMERS

10kV Single-Phase Transformer

Single-phase design · Rural distribution · Pole or floor mounting

01 / OVERVIEW

Source-backed product overview.

Read the supplied description before sharing project requirements.

Our 10kV singlephase transformer covers capacity range from 100 kVA to 500 kVA. Specially engineered for scatteredload and remotestation power supply in rural regions, it features lowloss performance, high reliability and simple installation, delivering stable support for rural powergrid upgrading projects.

We supply factorywholesale 10 kV singlephase transformers tailored for rural powergrid optimization. Ranging 100 kVA500 kVA, they fit rural operating characteristics including scattered loads, long transmission lines and large powersupply radius. The units can connect directly to 10 kV distribution networks, efficiently completing hightolow voltage conversion and effectively improving endofline voltage quality.

We adopt lowloss iron cores and fullcopper winding structures, balancing energysaving performance and overload capacity. They satisfy diverse power demands for rural residents, agricultural irrigation and smallscale processing. Our transformers run stably over long periods under harsh outdoor conditions such as high temperature, high humidity and sandwind exposure.

Manufactured complying with national and powerindustry standards, our units feature compact mechanical layout, highlevel protection and flexible installation modes. Both polemounting and floormount layout are supported. It greatly lowers construction difficulty and OPEX for rural grid renovation, making it core distribution equipment for rural revitalization and agriculturalnetwork upgrade.

PRODUCT / APPLICATION VIEW

See the equipment in context.

Product photography and application imagery are kept as separate visual roles for review.

10kV Single-Phase Transformer
Product view
Distribution equipment for a connected grid
Application context
Transformer equipment prepared for delivery
Application context

02 / FEATURES

Capabilities described in the source.

Lowloss & energysaving design

We deploy highpermeability coldrolled siliconsteel sheets plus optimized magneticflux structure. Both noload and load losses drop significantly. Longtime operation cuts electricity expenditure and satisfies ruralgrid energysaving & carbonreduction targets.

Optimized for rural singlephase loads

Purposebuilt for rural areas with dense singlephase loads. Compared with threephase alternatives, it better matches realworld consumption patterns. It mitigates threephase unbalance, lifting powersupply efficiency and voltage stability.

Robust outdoorgrade protection

Fullysealed construction and premiumgrade protection ratings deliver rainproof, dustproof and anticorrosion capability. Continuous operation is achievable under tough outdoor conditions, extending maintenancefree cycles and easing ruralsite O&M burdens.

Excellent shortcircuit & overload withstand capability

Windings use highstrength insulation and firm fastening techniques. Strong resistance against shortcircuit impact and outstanding shorttime overload performance handle seasonal load swings and equipment startup surges common in rural environments.

Compact footprint & easy installation

Smallbodied with moderate unit weight. It supports both polemount and concretefoundation floormount installation. Minimal civilworks required for fast deployment and small site occupation, wellsuited for complicated rural terrain and narrow installation spots.

Extended servicelife with fullcopper windings

Highpurity oxygenfree copper windings come as standard configuration. Superior conductivity, low heat generation and antiageing properties deliver long design life. It reduces replacement frequency and improves overall project economy.

03 / SPECIFICATIONS

Technical parameters.

Source table retained in full where supplied.

Rated capacity (kVA)HVLVEfficiencyDOE(2016)EfficiencyCSA(2023)
534.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others98.5898.47
1034.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others98.7098.60
1534.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others98.8298.73
2534.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others98.9598.87
37.534.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others99.0598.97
5034.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others99.1199.04
7534.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others99.1999.13
10034.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others99.2599.19
16734.5kV/19.92kV13.8kV/7.9kV13.2kV/7.6kV12.47kV/7.2kV or others120240V240480V347V600V or others99.3399.28

Need a verified configuration or export document package?

Send specification request

Before quotation, confirm: single-phase-specifications, missing-mentioned-cases, proof-and-claims.

04 / SELECTION NOTES

Match the equipment to the installation.

Electrical scope

Confirm voltage, capacity, frequency, vector group and tap range against the project brief.

Site conditions

Confirm indoor or outdoor placement, cooling, protection and environmental conditions.

Evidence review

Source claims and standards remain subject to final technical and document confirmation.

05 / APPLICATIONS

Where this equipment is positioned.

Confirm the installation environment and electrical requirements for this model.

Transformer equipment in a grid application
Grid distribution
Transformer equipment in an industrial application
Industrial facilities
Transformer equipment in a renewable-energy application
Renewable energy

06 / PROOF

Trace the supplied evidence.

The source document is retained in the private inventory as src-003. Claims, certifications and performance figures marked in the inventory remain pending confirmation before production publication.

Pending confirmation: single-phase-specifications, missing-mentioned-cases, proof-and-claims.

07 / SERVICE

Continue from selection to delivery.

Share the equipment requirements for a scoped technical conversation.

Selection

Send voltage, capacity, quantity and installation conditions.

Documentation

Confirm drawings, standards, test reports and acceptance requirements.

Support

Discuss installation, commissioning, training and after-sales scope.

Frequently asked questions.

Q: How is product quality guaranteed? A: All products are strictly manufactured per GB/T 1094, GB/T 6451 and other relevant standards. Every unit passes factory tests and type tests. We supply full certificates and test reports. Premiumgrade raw materials are adopted for core components. Free maintenance and replacement are available within warranty for qualified failures.

Q: Do you support fullcopper / aluminium winding customization? A: Fullcopper winding is our standard configuration. We offer coppervsaluminium comparison proposals upon project request. Copperwound units achieve lower loss and longer service life; aluminiumwound versions provide better costperformance for alternative selection.

Q: What is your typical order leadtime? A: Conventional 100500 kVA models are kept in stock and ship within 37 days after order confirmation. Customspec or bulk orders take roughly 1525 days production time, subject to contract terms.

Q: What about transportation & packaging? A: Packaging includes solidwood base, moistureresistant film and steelband fastening. We support seafreight and general logistics for domestic directtosite delivery. Exportgrade inspectionpassed packaging is provided for overseas orders with full anticollision and rainshield protection.

Q: Can units get damaged during transit? A: Anticollision and antitipping reinforcement are finished before exfactory. Full logistics insurance is covered. Onsite boxopening inspection is allowed upon arrival. We provide free repair or replacement for appearance / performance damage caused by transportation.

Q: What standard accessories are supplied? A: Standard accessories: nameplate, tapchanger, lifting lugs, sealing gaskets and mounting bolts. Optional extras include thermometer, oillevel indicator, gas relay, grounding cable and more to match project requirements.

Q: What advantages vs threephase transformers of equal capacity? A: Singlephase units fit rural singlephaseload profiles better, reduce unbalance losses, occupy less space and cost less capital. Installation is more flexible for scattered stations & enduser power supply with lower comprehensive O&M cost.

Q: Can this transformer be installed directly outdoors in rural locations? A: Yes. It is engineered as outdoortype equipment with protection ratings meeting openair operating demands. Polemount installation is feasible without dedicated distribution rooms; commissioning is completed by simple onsite wiring.

Q: What aftersales and technical support do you provide? A: Lifelong technical consultation is available. Nonartificial faults get free service within warranty scope. We assist with onsite installation guidance, commissioning and operator training, and deliver rapid aftersales response even for remote rural sites.

Project references in the supplied document.

Distribution transformers serve as the voltageconversion backbone for all gridconnected industries. Voltage rating, thermal class and mounting configuration can be customized for target applications.

Thailand Bangkok 11 sets of KYN28A24 switchgear + SCB14 drytype transformer complete project

15 Units 22kV Oilimmersed Transformer Industrial Park Distribution in Vietnam Project

20 sets of 11kV oilimmersed transformers grid transformation project in Nigeria

Grid Upgrade Project for 8 35kV Power Transformers in Kazakhstan

Gridconnected project of 12 PV transformers + ring cabinets in Java, Indonesia

Only project records with supplied detail material have independent routes. Other named references require confirmation.

NEXT STEP

Discuss 10kV Single-Phase Transformer.

Send voltage, capacity, quantity and installation conditions for a scoped response.

Request an inquiry Contact us